Metal Back Boxes, White Pattress, Dry Lining Fast-Fix Boxes

!

METAL BACK BOX 16MM SWITCH

52620
52620
!
10 + rate = 25.5p
METAL BACK BOX 16MM SWITCH

METAL BACK BOX 25MM 1GANG

52621
52621
!
10 + rate = 28.9p
METAL BACK BOX 25MM 1GANG

METAL BACK BOX 25MM 2GANG

52623
52623
!
10 + rate = 32.3p
METAL BACK BOX 25MM 2GANG

METAL BACK BOX 35MM 1GANG

52622
52622
!
10 + rate = 32.3p
METAL BACK BOX 35MM 1GANG

METAL BACK BOX 35MM 2GANG

52624
52624
!
10 + rate = 41.65p
METAL BACK BOX 35MM 2GANG

METAL BACK BOX 47MM

52626
52626
!
METAL BACK BOX 47MM

METAL BOX SPLIT/BX DOUBLE

52625
52625
!
For mounting 2 Single Accessories side by side

Dual Accesory Box - One + Two 35mm

52612
!

16mm 1 Gang Pattress

Larger picture
KM83
!

25mm/47mm 1 Gang Pattress

Larger picture
KM33
!

25mm/47mm 2 Gang Pattress

Larger picture
KM34
!

DUAL PATTRESS TRADE RANGE

K41
K41
!
DUAL PATTRESS CAN BE MOUNTED ANY WAY UP

FAST-FIX 1GANG-TRADE RANGE

K26
K26
!
For Switches and Single Sockets. For fast fixing into cavity wall structures and dry lining partions

FAST-FIX 2GANG-TRADE RANGE

K27
K27
!
For Switches and Single Sockets. For fast fixing into cavity wall structures and dry lining partions

SPLIT/BX FASTFIX

52627
52627
!
For mounting 2 Single Accessories side by side

Round Ceiling Dry Lining Box

K01
!

Fire & Acoustic Rated Metal Dry Lining Back Boxes

15486
!

1 gang and 2 gang boxes in both 35mm and 47mm depths. As simple to install as a standard cavity wall box.  No additional components to purchase or install.

 

Simple and quick to install saving time and money.

Unique spring loaded lugs.

Substantial amount of cable entries.

Earth terminal fitted.

 

With potential fire temperatures in excess of 1000 C, the use of metal in the FlameGuard design helps maintain its position within the wall until the wall loses its structural integrity. “The FlameGuard intumescent seal, when exposed to fire, forms a dense carbon char which separates and insulates the substrate from the heat of the fire. The expanded seal eliminates the flow of air through the void and thereby starves

the fire of vital elements for combustion.” The fire & sound integrity is not impaired

when the FlameGuard back boxes are installed back to back. FlameGuard back boxes have been tested and conform to both fire and acoustic BS EN standards Complies with Building Regulations. Part B (Fire Safety) Part E (Resistance to the Passage of Sound)

 

The intumescent layer within the box starts to expand at 190 degrees Celsius and continues to expand as the temperature increases filling the metal box cavity.

 

The spring loaded fixing lugs are retracted in preparation for box installation (Handles 7mm upwards). With the box in position the fixing lugs are released, locking the box in place in readiness for the installation of the appropriate accessory. The fire and acoustic integrity of the wall has now been restored.